ATC PROGRAM GUIDE FOR FUJI INVERTER
INVERTER PARAMETER VALUES
|
Parameter
|
Setting
|
|
P000-Data Protection
|
Set to 0 for change,1 to write protect
|
|
P001-Motor Max Speed
|
4500-6000 depends on motor
|
|
P002-Acceleration Time
|
2 (for most motor)
|
|
P003-Deceleration Time
|
2 (for most motor)
|
|
P053-Motor Code
|
105 or 107 (depends on motor)
|
|
P078-PE-Feedback Control
|
1-Use
|
|
P079-NTC Thermistor
|
1-Use
|
|
P106-ASRP-Gain (ORT H Gear)
|
25
|
|
P115-ASR Integration Time (ORT H Gear)
|
0
|
|
P201-Spindle/PE Ratio
|
1 - 1:1
|
|
P202-A/B Phase Select
|
1-Phase B leading in for direction
|
|
P203-Pulse Select
|
0-1024 line encoder (default)
|
|
P204-Acc/Dec Mode
|
1-Use
|
|
P205-Internal Stop Position
|
Use 206 to set this to index position
|
|
P206-Auto Reading of stop position
|
Set to 1 when spindle & pin on carousel
|
|
|
are alignel for tool unloading/loading
|
|
P217-APR P-Gain (ORT H Gear)
|
25
|
|
P221-Completion Range (Width)
|
12 pulses
|
|
P225-Re-ORT Mode
|
1-After one revolution
|
INVERTER PARAMETER PROGRAMMING
1.Press and hold the [MODE] button while using the [UP] and [DOWN] button to change parameter number.
2. When [MODE] is released, the parameter value will be displayed for a few seconds. Use [UP] and [DOWN] to change the parameter value as desired.
3. Press [SET] to save the changes to the parameter.
4. P100 must be set to 1 to access P101 and above.
5. P200 must be set to 1 to access P201 and above.