Special PLC functions for the Parameter Menu
PLC program: t400bm21v3p.src, t400bmae.src.
Parameter 170
|
Bit # |
Value |
Function |
|
Bit 0 |
1 |
6 position Electrical turret |
|
Bit 1 |
2 |
4 position Electrical turret |
|
Bit 2 |
4 |
8 position Electrical turret |
|
Bit 3 |
8 |
Gear Selection. Selection between 21xx (3 sensors) and 16xx (2sensors). Default: 21xx series lathe. |
Parameter 178
|
Bit # |
Value |
Function |
|
Bit 11 |
2048 |
Door Switch NC / NO. Default – NC |
Add 2048 into the existing value in parameter 178 to change door switch state.
How to add tool turret function
Examples,
1. KL 2140 lathe with 6 position turret.
Parameter 6 - 1
Parameter 170 - 1. and “cnc10.tch.bak” should be renamed to “cnc10.tch” you can rename a file name by going to F7 <utility> -> F5 <file OP.> -> highlight the file you wish you change its name. -> F7 <Rename>
2. KL 1640 lathe with 4 position turret.
Parameter 6 - 1
Parameter 170 – 2 + 8 = 10